16kW Renovation Project
Indoor & Outdoor Model: Panasonic S/U-60PE3R5Z (High Static Ducted Inverter)
Performance / Capacity:
Heating Capacity: 6.0 kW
Cooling Capacity: 6.0 kW
Air Distribution System (3 Outlets Total):
Bedroom 1: 1 × Outlet Diffuser
Bedroom 2: 1 × Outlet Diffuser
Bedroom 3: 1 × Outlet Diffuser
Return Air Intake: 1 × Return Air Grille with Washable Filter
Primary Control: Panasonic Wall Controller with Built-in Wi-Fi (CZ-RTC6BLW)
Zone Controller Model: Panasonic Zone Controller (CZ-CAPZ1S)
Connectivity: Built-in Wi-Fi Mobile App Control (Panasonic Comfort Cloud / Zone App)
Configured Zones (3 Independent Bedroom Zones):
Zone 1: Bedroom 1
Zone 2: Bedroom 2
Zone 3: Bedroom 3
On-site engineering design and layout for supply and return duct runs to ensure whisper-quiet operation and balanced airflow across all three bedrooms.
Work area protection and floor coverings laid down before installation starts.
Supply and suspend/mount the Panasonic high-static ducted fan coil unit securely in the roof space or underfloor cavity.
Supply and install thermally insulated, acoustic flexible ducting to all 3 designated bedroom outlets.
Supply and install 3 ceiling/floor air diffusers and 1 return air grille.
Supply and install motorized dampers integrated with the CZ-CAPZ1S 3-zone control module.
Position the outdoor condenser unit on heavy-duty rubber vibration-isolation mounting pads/brackets.
Run refrigeration-grade insulated copper pipework, electrical interconnecting cable, and gravity condensate drain line.
Nitrogen pressure test, deep system evacuation/vacuum pump pull-down, and refrigerant trim check.
Electrical mains run and connection from switchboard/sub-board.
Supply and install weatherproof outdoor isolator switch.
Commissioning, safety testing, and issue of an Electrical Certificate of Compliance (CoC)
Full system airflow balancing and individual motorized zone damper calibration.
Wi-Fi pairing and setup for the wall controller and mobile app.
Client demonstration on mode scheduling, individual bedroom airflow adjustment, and washable filter cleaning.
Site clean-up and disposal of packaging.
Equipment/Product Warranty: 5 Years manufacturer warranty on all Panasonic indoor/outdoor units, compressors, and parts.
Zone & Wall Controller Warranty: 5 Years on Panasonic controllers.
Workmanship/Installation Guarantee: 5 Years comprehensive installation warranty covering ducting connections, dampers, pipework, and labour.
Compliance Certification: Electrical Certificate of Compliance (CoC) provided upon completion.